MiPNet14.06 Instrumental O2 background: Difference between revisions
From Bioblast
(Undo revision 187763 by Antunes Diana (talk)) |
Tindle Lisa (talk | contribs) No edit summary Β |
||
(31 intermediate revisions by 10 users not shown) | |||
Line 1: | Line 1: | ||
{{OROBOROS | {{Template:OROBOROS support page name}} | ||
{{Publication | {{Publication | ||
|title=[[Image:O2k- | |title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. | ||
|info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/6/65/MiPNet14.06_InstrumentalO2Background.pdf |Bioblast pdf]] Β» [http://www.bioblast.at/index.php/File:MiPNet14.06_InstrumentalO2Background.pdf Versions] | |info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/6/65/MiPNet14.06_InstrumentalO2Background.pdf |Bioblast pdf]] Β» [http://www.bioblast.at/index.php/File:MiPNet14.06_InstrumentalO2Background.pdf Versions] | ||
|authors=Oroboros | |authors=Oroboros | ||
|year= | |year=2023-10-19 | ||
|journal=Mitochondr Physiol Network | |journal=Mitochondr Physiol Network | ||
|abstract= | |abstract=TimΓ³n-GΓ³mez A, Grings M, Baglivo E, Schmitt S, Gnaiger E (2023) O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. Mitochondr Physiol Network 14.6(09):1-16. | ||
Β | {{MiPNet pdf page linking to MitoPedia}} | ||
:Β» Product: [[O2k-FluoRespirometer]], [[Oroboros O2k-Catalogue |O2k-Catalogue]] | :Β» Product: [[O2k-FluoRespirometer]], [[Oroboros O2k-Catalogue |O2k-Catalogue]] | ||
|mipnetlab=AT_Innsbruck_Oroboros | |mipnetlab=AT_Innsbruck_Oroboros | ||
}} | }} | ||
: | == Keywords == | ||
{{Template:Keywords: Chamber volume}} | |||
Β | |||
Β | |||
Β | |||
Β | |||
'''Acknowledgements''' | |||
[[File:Template NextGen-O2k.jpg|left|400px|link=NextGen-O2k]] | |||
<br/> | |||
<br/> | |||
<br/> | |||
<br/> | |||
{{Labeling | {{Labeling | ||
|area=Respiration, Instruments;methods | |area=Respiration, Instruments;methods | ||
|instruments=Oxygraph-2k, O2k-Manual | |instruments=Oxygraph-2k, O2k-Manual | ||
|additional=DatLab, O2k-SOP | |additional=DatLab, O2k-SOP, DL7, System, MitoFit2022QC | ||
}} | }} |
Latest revision as of 17:19, 19 October 2023
MiPNet14.06 Instrumental O2 background |
O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. |
Β» Β» Versions
Oroboros (2023-10-19) Mitochondr Physiol Network
Abstract: TimΓ³n-GΓ³mez A, Grings M, Baglivo E, Schmitt S, Gnaiger E (2023) O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. Mitochondr Physiol Network 14.6(09):1-16.
- Β» Current O2k-series: NextGen-O2k Series XB and O2k Series J
- Β» Current software versions DatLab 8.0: MitoPedia: DatLab
- Further details: Β» MitoPedia: O2k-Open Support
- Β» Product: O2k-FluoRespirometer, O2k-Catalogue
β’ O2k-Network Lab: AT_Innsbruck_Oroboros
Keywords
- Β»Bioblast links: Chamber volume - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>>
- Β» Volume
- Units: Liter [L]; 1 L = 1 dm3 = 10-3 m3; 1 mL = 1 cm3; 1 Β΅L = 1 mm3
- Β» Volume
- On chamber volume
- Components of the experimental O2k-chambers
- Β» Stirrer-Bar\white PVDF\15x6 mm
- Β» Stirrer-Bar sV\white PVDF\11.5x6.2 mm
- Β» Stopper\black PEEK\conical Shaft\central Port
- Β» Stopper sV\black PEEK\conical Shaft\central Port
- Β» O-ring\Viton\12.5x1 mm
- Β» O-ring sV\Viton\9.5x1 mm
- Β» Volume-Calibration Ring
- Β» Volume-Calibration Ring sV
- Β» Stopper-Spacer
- Β» Cover-Slip\black
- Β» O2k-Chamber Holder
- Β» O2k-Chamber Holder sV
- Β» OroboPOS-Holder
- Β» OroboPOS-Holder sV
- Maintencance
Acknowledgements
Labels: MiParea: Respiration, Instruments;methods
HRR: Oxygraph-2k, O2k-Manual
DatLab, O2k-SOP, DL7, System, MitoFit2022QC