Volume-Calibration Ring sV: Difference between revisions
From Bioblast
No edit summary |
Tindle Lisa (talk | contribs) No edit summary Β |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{ | {{Technical support}} | ||
|description='''Volume-Calibration Ring sV''' (A or B), white PVDF, attached to [[Stopper sV\black PEEK\conical Shaft\central Port | PEEK O2k-Stopper sV]]. | __TOC__ | ||
{{MitoPedia without banner | |||
|abbr= | |||
|info= | |description=[[Image:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]]'''Volume-Calibration Ring sV''' (A or B), white PVDF, attached to [[Stopper sV\black PEEK\conical Shaft\central Port | PEEK O2k-Stopper sV]]. | ||
|info=[https://www.oroboros.at/index.php/product/volume-calibration-ring-sv/ '''Product details and purchase information'''] | |||
}} | }} | ||
__TOC__ | __TOC__ | ||
{{Template:Technical support integrated}} | {{Template:Technical support integrated}} | ||
== Technical support == | == Technical support == | ||
Line 16: | Line 17: | ||
[[Image:Volume calibration ring A+B aluminum for Stopper.jpg|right|400px]] | [[Image:Volume calibration ring A+B aluminum for Stopper.jpg|right|400px]] | ||
== Keywords == | |||
{{Template:Keywords: Chamber volume}} | |||
{{MitoPedia O2k and high-resolution respirometry | |||
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | |||
}} |
Latest revision as of 11:25, 11 November 2020
Volume-Calibration Ring sV |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Volume-Calibration Ring sV (A or B), white PVDF, attached to PEEK O2k-Stopper sV.
Reference: Product details and purchase information
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Technical support
- Volume calibration of the 0.5-mL O2k-chamber
- Loosen the stopper fixation rings (A) and (B) with the Allen key.
- Follow the instructions in the O2k-Manual: MiPNet22.11 O2k-FluoRespirometer manual
- Tighten the screws of the fixation rings (A) and (B) gently with the Allen key to ensure that the calibration ring cannot be displaced. Tightening the screw with too much force may damage the thread of the calibration ring. Check for a sufficient fixation by trying to rotate the calibration ring.
- Volume calibration of the 0.5-mL O2k-chamber
Keywords
- Β»Bioblast links: Chamber volume - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>>
- Β» Volume
- Units: Liter [L]; 1 L = 1 dm3 = 10-3 m3; 1 mL = 1 cm3; 1 Β΅L = 1 mm3
- Β» Volume
- On chamber volume
- Components of the experimental O2k-chambers
- Β» Stirrer-Bar\white PVDF\15x6 mm
- Β» Stirrer-Bar sV\white PVDF\11.5x6.2 mm
- Β» Stopper\black PEEK\conical Shaft\central Port
- Β» Stopper sV\black PEEK\conical Shaft\central Port
- Β» O-ring\Viton\12.5x1 mm
- Β» O-ring sV\Viton\9.5x1 mm
- Β» Volume-Calibration Ring
- Β» Volume-Calibration Ring sV
- Β» Stopper-Spacer
- Β» Cover-Slip\black
- Β» O2k-Chamber Holder
- Β» O2k-Chamber Holder sV
- Β» OroboPOS-Holder
- Β» OroboPOS-Holder sV
- Maintencance
MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry