Difference between revisions of "Gnaiger 2008 POS"
Line 6: | Line 6: | ||
|journal=John Wiley | |journal=John Wiley | ||
|abstract=Several features distinguish '''[[high-resolution respirometry]]''' from traditional oxygraphs, combined in the new [[Oxygraph-2k]] (O2k, OROBOROS INSTRUMENTS, Innsbruck, Austria). The specifications are unique: the limit of detection of respiratory flux is 1 pmol∙s<sup>-1</sup>∙cm<sup>-3</sup> (0.001 µM∙s<sup>-1</sup>) and the limit of detection of oxygen concentration extends to 0.005 µM O<sub>2</sub>. For the non-specialist, the O2k provides robustness and reliability of instrumental performance. With small amounts of sample and correspondingly low respiratory flux per volume, the oxygen capacity of the system is exhausted slowly, allowing sufficient time to evaluate the stability of respiratory activity in each metabolic state and to permit complex titration regimes in intact cells or in permeabilized cells and tissues. To increase throughput in research with cell cultures and in the pharmacological arena, user-friendly features make it possible to apply several instruments in parallel, each O2k with two independent chambers. | |abstract=Several features distinguish '''[[high-resolution respirometry]]''' from traditional oxygraphs, combined in the new [[Oxygraph-2k]] (O2k, OROBOROS INSTRUMENTS, Innsbruck, Austria). The specifications are unique: the limit of detection of respiratory flux is 1 pmol∙s<sup>-1</sup>∙cm<sup>-3</sup> (0.001 µM∙s<sup>-1</sup>) and the limit of detection of oxygen concentration extends to 0.005 µM O<sub>2</sub>. For the non-specialist, the O2k provides robustness and reliability of instrumental performance. With small amounts of sample and correspondingly low respiratory flux per volume, the oxygen capacity of the system is exhausted slowly, allowing sufficient time to evaluate the stability of respiratory activity in each metabolic state and to permit complex titration regimes in intact cells or in permeabilized cells and tissues. To increase throughput in research with cell cultures and in the pharmacological arena, user-friendly features make it possible to apply several instruments in parallel, each O2k with two independent chambers. | ||
|mipnetlab=AT_Innsbruck_Gnaiger E, AT Innsbruck | |mipnetlab=AT_Innsbruck_Gnaiger E, AT Innsbruck OROBOROS | ||
|discipline=Mitochondrial Physiology | |discipline=Mitochondrial Physiology | ||
}} | }} | ||
Line 18: | Line 18: | ||
|substratestates=ROX | |substratestates=ROX | ||
|instruments=Oxygraph-2k, TIP2k | |instruments=Oxygraph-2k, TIP2k | ||
|discipline=Mitochondrial Physiology | |discipline=Mitochondrial Physiology | ||
}} | }} |
Revision as of 07:00, 16 August 2013
Gnaiger E (2008) Polarographic oxygen sensors, the oxygraph and high-resolution respirometry to assess mitochondrial function. In: Mitochondrial Dysfunction in Drug-Induced Toxicity (Dykens JA, Will Y, eds) John Wiley: 327-352. |
Gnaiger E (2008) John Wiley
Abstract: Several features distinguish high-resolution respirometry from traditional oxygraphs, combined in the new Oxygraph-2k (O2k, OROBOROS INSTRUMENTS, Innsbruck, Austria). The specifications are unique: the limit of detection of respiratory flux is 1 pmol∙s-1∙cm-3 (0.001 µM∙s-1) and the limit of detection of oxygen concentration extends to 0.005 µM O2. For the non-specialist, the O2k provides robustness and reliability of instrumental performance. With small amounts of sample and correspondingly low respiratory flux per volume, the oxygen capacity of the system is exhausted slowly, allowing sufficient time to evaluate the stability of respiratory activity in each metabolic state and to permit complex titration regimes in intact cells or in permeabilized cells and tissues. To increase throughput in research with cell cultures and in the pharmacological arena, user-friendly features make it possible to apply several instruments in parallel, each O2k with two independent chambers.
• O2k-Network Lab: AT_Innsbruck_Gnaiger E, AT Innsbruck OROBOROS
Labels: MiParea: Respiration, Instruments;methods
Organism: Mouse
Tissue;cell: Blood cells
Preparation: Intact cells, Permeabilized cells, Permeabilized tissue
Regulation: Coupling efficiency;uncoupling, Uncoupler Coupling state: LEAK, ROUTINE, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property.
HRR: Oxygraph-2k, TIP2k