MiPNet12.10 TIP2k-manual: Difference between revisions
No edit summary |
No edit summary |
||
Line 9: | Line 9: | ||
'''Direct Control Mode:''' Operation mode for delivering a defined volume in a short pulse. A number of cycles, N, can be defined, and the duration of the interval from injection to injection determined, repeating the process N times. Several such steps can be programmed to run in sequence to give an entire TIP program. | '''Direct Control Mode:''' Operation mode for delivering a defined volume in a short pulse. A number of cycles, N, can be defined, and the duration of the interval from injection to injection determined, repeating the process N times. Several such steps can be programmed to run in sequence to give an entire TIP program. | ||
ย ย | ย ย | ||
'''Feedback Control Mode:''' Operation mode to reach and maintain a | '''Feedback Control Mode:''' Operation mode to reach and maintain a certain parameter (e.g. oxygen concentration) by automatic TIP injections. | ||
|keywords=HRR-TIP2k | |keywords=HRR-TIP2k | ||
|info=[http://www.oroboros.at/index.php?id=o2k-tip2k-manual MiPNet12.10] | |info=[http://www.oroboros.at/index.php?id=o2k-tip2k-manual MiPNet12.10] | ||
Line 17: | Line 17: | ||
|articletype=Protocol; Manual, MiPNet-online Publication | |articletype=Protocol; Manual, MiPNet-online Publication | ||
}} | }} | ||
==Info== | ==Info== | ||
Revision as of 11:32, 20 October 2010
Fasching M, Lukas Gradl L, Gradl P, Erich Gnaiger E. Titration-Injection microPump TIP2k. User manual. Mitochondr. Physiol. Network 12.10. |
ยป MiPNet12.10
Fasching M, Lukas Gradl L, Gradl P, Erich Gnaiger E (
) Mitochondr. Physiol. Network
Abstract: TIP2k - 2-Channel Titration-Injection microPump: The TIP2k provides unique advantages for applications which require highest accuracy of titration volumes and automatic control of complex titration-injection protocols. The TIP2k was specially developed for the Oxygraph-2k. The main modes of operation are automatic multi-step injections, continuous injections for steady-state respirometry, (both operated form the direct control mode), and feedback controlled operation.
Direct Control Mode: Operation mode for delivering a defined volume in a short pulse. A number of cycles, N, can be defined, and the duration of the interval from injection to injection determined, repeating the process N times. Several such steps can be programmed to run in sequence to give an entire TIP program.
Feedback Control Mode: Operation mode to reach and maintain a certain parameter (e.g. oxygen concentration) by automatic TIP injections. โข Keywords: HRR-TIP2k
โข O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels:
HRR: Oxygraph-2k, TIP2k, DatLab Software; Separate Application"DatLab Software; Separate Application" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., Method"Method" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
Info
MiPNet09.10 is integrated in MiPNet12.10 TIP2k-Manual.