== Signal of the O2k-Core and add-on modules ==
== Signal of the O2k-Core and add-on modules ==
Three electronic channel types are available in the [[O2k-MultiSensor |O2k-MultiSensor system]]. All channels are available twofold, for O2k-Chambers A and B (left and right):
[[Image:Oxygraph-2k-Concept.jpg|right|300px|O2k-Concept.jpg]].
Three electronic channel types are available in the [[O2k-MultiSensor |O2k-MultiSensor system]]. All channels are available twofold (dual-data), for O2k-Chambers A and B (left and right), based on signals (numerical) sent at a fixed data sampling time interval (typical: 1 s or 2 s; range 0.2 s to >10 s):


# O<sub>2</sub> channel with electric current (ampere  [Amp]) as the primary signal, which is converted to a voltage (volt [V]) as the raw signal. The O2k-Core supports not only the O<sub>2</sub> channel (O2 plug), but also the channel types 2 and 3 for the add-on modules.
: 1. O<sub>2</sub> channel with electric current (ampere  [Amp]) as the primary signal, which is converted to a voltage (volt [V]) as the raw signal. The [[O2k-Core]] supports not only the O<sub>2</sub> channel (O2 plug), but also the channel types 2 and 3 for the add-on modules.
# Amp channel: The amperometric channel of the O2k, has electric current (ampere [Amp]) as the primary signal, which is converted to a voltage (volt [V]) as the raw signal. The Amp-Channel is used with the [[O2k-Fluo LED2-Module]] and the [[O2k-NO Amp-Module]].
: 2. Amp channel: The amperometric channel of the O2k (Amp plug), has electric current (ampere [Amp]) as the primary signal, which is converted to a voltage (volt [V]) as the raw signal. The Amp-Channel is used with the [[O2k-Fluo LED2-Module]] and the [[O2k-NO Amp-Module]].
# pX channel with electric potential (volt [V]) as the primary and raw signal (BNC plug for the ion sensitive electrode, ISE; and separate plug for the pX reference electrode, Ref).
: 3. pX channel with electric potential (volt [V]) as the primary and raw signal (BNC pX plug for the ion sensitive electrode, ISE; and separate plug for the pX reference electrode, Ref).
: 4. Events: Automatic events (e.g. from the [[TIP2k]]) and manually triggered events carry information on a time point during the experiment, a short event name (text), and a longer string of comments (text).
<br />
<br />
'''System channels''', for instrumental control, not separated into O2k-Chamber A and B (single-data), based on signals (numerical) sent at the same fixed data sampling time interval:


Additional channel types are available in the [[NextGen-O2k]]:
: 5a. Block temperature: Measured block temperature equivalent to the experimental temperature in the O2k-Chambers at steady state [°C].
: 4. Spectrophotometric channel.
: 5b. Peltier power (system channel): Relative heating or cooling power of the Peltier system.
: 5. Dual-fluo channel.
: 5c. Barometric pressure (system channel): Measured barometric pressure [kPa].
: 5d. Ambient temperature (system channel): Measured temperature of room air (O2k-Series G upwards) [°C].
: 5d. External temperature (system channel): Temperature measured with an independently placed thermistor (O2k-Series G upwards) [°C].


'''NextGen-O2k''': additional channel types are available in the [[NextGen-O2k]]:
: 6. Dual-fluo channel.
: 7. Spectrophotometric channel.
== O2k output ==


== Output ==
The 'output' of a channel is the finally important infomation, which may be summarized in a data base. Three types of output can be derived from the signal of the O2k channels:  
The 'output' of a channel is the finally important infomation, which may be summarized in a data base. Three types of output can be derived from the signal of the O2k channels:  
: '''A''': Concentration (e.g. O<sub>2</sub>; Ca<sup>2+</sup>).
: '''I''': Concentration. Examples: O<sub>2</sub>; Ca<sup>2+</sup>; amount of substrance per volume [1 µM = 1 µmol·dm<sup>-3</sup> = 1 nmol·ml<sup>-1</sup>].
: '''B''': Flow, flux, rate (e.g. O<sub>2</sub> consumption; H<sub>2</sub>O<sub>2</sub> production).
: '''II''': Flow, flux, rate. Examples: O<sub>2</sub> consumption; H<sub>2</sub>O<sub>2</sub> production; volume-specific flux is the negative or positive time derivative of concentration over time, frequently multiplied by 1,000 [pmol·s<sup>-1</sup>·ml<sup>-1</sup>]. Volume-specific flux normalized for the cell density [10<sup>6</sup>·ml<sup>-1</sup>] is flow [pmol·s<sup>-1</sup>·ml<sup>-1</sup>]. Volume-specific flux normalized for the mass density of the sample in the O2k-Chamber [mg·ml<sup>-1</sup>] is mass-specific flux [pmol·s<sup>-1</sup>·mg<sup>-1</sup>]. Flux in any respiratory state normalized for flux in a defined reference state is a rate [dimensionless] or [[flux control ratio]].
: '''C''': Force, potential (e.g. TMRM and Safranin for mt-membrane potential; redox potential from cytochrome or NADH redox states).
: '''III''': Force, potential (e.g. TMRM and Safranin for mt-membrane potential; redox potential from cytochrome or NADH redox states).
<br />
<br />


: 1. O<sub>2</sub> channel - [[O2k-Core]]: Output type '''A''' and '''B'''.
: 1. O<sub>2</sub> channel - [[O2k-Core]]: Output type I and II.
: 2a. Amp channel - [[O2k-Fluo LED2-Module]]: The focus of the output depends on the specific fluorophore. Output type '''A''', '''B''', or '''C''', or any combination may relate to the primary level of interest.
: 2a. Amp channel - [[O2k-Fluo LED2-Module]]: The focus of the output depends on the specific fluorophore. Output type I, II, or III, or any combination may relate to the primary level of interest.
: 2b. Amp channel - [[O2k-NO Amp-Module]]: Output type '''A''' and '''B'''.
: 2b. Amp channel - [[O2k-NO Amp-Module]]: Output type I and II.
: 3a. pX channel - [[O2k-TPP+ ISE-Module]]: Output type '''C'''.
: 3a. pX channel - [[O2k-TPP+ ISE-Module]]: Output type III.
: 3b. pX channel - [[O2k-pH ISE-Module]]: Output type '''A''' and '''B'''.
: 3b. pX channel - [[O2k-pH ISE-Module]]: Output type I and II.
: 4. Events - [[O2k-Core]] and [[TIP2k]]


: 4. Spectrophotometric channel - [[NextGen-O2k]]: Output type '''D''' (three plots for redox states of cytochromes ''aa''<sub>3</sub>, ''b'', and ''c''.
: 6. Single-fluo channel - [[NextGen-O2k]]: Plots of one selected wavelength can be selected for recording. Output type I(1), II(1), III(1) depends on the fluorophore.
: 5. Dual-fluo channel - [[NextGen-O2k]]: Plots of two selected wavelengths can be selected for simultaneous recording. Output type '''E1''', '''E2''', .. depends on the fluorophore.
: 7. Dual-fluo channel - [[NextGen-O2k]]: Plots of two selected wavelengths can be selected for simultaneous recording. Output type I(2), II(2), III(2) depends on the fluorophore.
: 8. Spectrophotometric channel - [[NextGen-O2k]]: Output type IV (three plots for redox states of cytochromes ''aa''<sub>3</sub>, ''b'', and ''c''.

Revision as of 17:00, 28 July 2015

Signal of the O2k-Core and add-on modules

O2k-Concept.jpg

.

Three electronic channel types are available in the O2k-MultiSensor system. All channels are available twofold (dual-data), for O2k-Chambers A and B (left and right), based on signals (numerical) sent at a fixed data sampling time interval (typical: 1 s or 2 s; range 0.2 s to >10 s):

1. O2 channel with electric current (ampere [Amp]) as the primary signal, which is converted to a voltage (volt [V]) as the raw signal. The O2k-Core supports not only the O2 channel (O2 plug), but also the channel types 2 and 3 for the add-on modules.
2. Amp channel: The amperometric channel of the O2k (Amp plug), has electric current (ampere [Amp]) as the primary signal, which is converted to a voltage (volt [V]) as the raw signal. The Amp-Channel is used with the O2k-Fluo LED2-Module and the O2k-NO Amp-Module.
3. pX channel with electric potential (volt [V]) as the primary and raw signal (BNC pX plug for the ion sensitive electrode, ISE; and separate plug for the pX reference electrode, Ref).
4. Events: Automatic events (e.g. from the TIP2k) and manually triggered events carry information on a time point during the experiment, a short event name (text), and a longer string of comments (text).


System channels, for instrumental control, not separated into O2k-Chamber A and B (single-data), based on signals (numerical) sent at the same fixed data sampling time interval:

5a. Block temperature: Measured block temperature equivalent to the experimental temperature in the O2k-Chambers at steady state [°C].
5b. Peltier power (system channel): Relative heating or cooling power of the Peltier system.
5c. Barometric pressure (system channel): Measured barometric pressure [kPa].
5d. Ambient temperature (system channel): Measured temperature of room air (O2k-Series G upwards) [°C].
5d. External temperature (system channel): Temperature measured with an independently placed thermistor (O2k-Series G upwards) [°C].

NextGen-O2k: additional channel types are available in the NextGen-O2k:

6. Dual-fluo channel.
7. Spectrophotometric channel.


O2k output

The 'output' of a channel is the finally important infomation, which may be summarized in a data base. Three types of output can be derived from the signal of the O2k channels:

I: Concentration. Examples: O2; Ca2+; amount of substrance per volume [1 µM = 1 µmol·dm-3 = 1 nmol·ml-1].
II: Flow, flux, rate. Examples: O2 consumption; H2O2 production; volume-specific flux is the negative or positive time derivative of concentration over time, frequently multiplied by 1,000 [pmol·s-1·ml-1]. Volume-specific flux normalized for the cell density [106·ml-1] is flow [pmol·s-1·ml-1]. Volume-specific flux normalized for the mass density of the sample in the O2k-Chamber [mg·ml-1] is mass-specific flux [pmol·s-1·mg-1]. Flux in any respiratory state normalized for flux in a defined reference state is a rate [dimensionless] or flux control ratio.
III: Force, potential (e.g. TMRM and Safranin for mt-membrane potential; redox potential from cytochrome or NADH redox states).


1. O2 channel - O2k-Core: Output type I and II.
2a. Amp channel - O2k-Fluo LED2-Module: The focus of the output depends on the specific fluorophore. Output type I, II, or III, or any combination may relate to the primary level of interest.
2b. Amp channel - O2k-NO Amp-Module: Output type I and II.
3a. pX channel - O2k-TPP+ ISE-Module: Output type III.
3b. pX channel - O2k-pH ISE-Module: Output type I and II.
4. Events - O2k-Core and TIP2k
6. Single-fluo channel - NextGen-O2k: Plots of one selected wavelength can be selected for recording. Output type I(1), II(1), III(1) depends on the fluorophore.
7. Dual-fluo channel - NextGen-O2k: Plots of two selected wavelengths can be selected for simultaneous recording. Output type I(2), II(2), III(2) depends on the fluorophore.
8. Spectrophotometric channel - NextGen-O2k: Output type IV (three plots for redox states of cytochromes aa3, b, and c.