Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "OroboPOS"

From Bioblast
ย 
(61 intermediate revisions by 12 users not shown)
Line 1: Line 1:
{{Product
{{Technical support}}
|description=The '''OroboPOS''' is a polarographic oxygen sensor (POS), with an amperometric mode of operation. The electrochemical POS was introduced by L Clark, with application of a polarization voltage (0.6 to 0.8 V) and measurement of a current (amperometric), which is converted to a voltage.
__TOC__
{{MitoPedia without banner
|abbr=
|description=[[Image:OroboPOS.JPG|right|180px]]
The '''OroboPOS''' is a polarographic oxygen sensor (POS), with an amperometric mode of operation. The OroboPOS meets the highest quality criteria in terms of linearity, stability and sensitivity of the signal. The Clark type polarographic oxygen sensor (POS) remains the gold standard for measuring dissolved oxygen in biomedical, environmental and industrial applications over a wide dynamic oxygen range.
ย 
It consists of a gold cathode, a silver/silverchloride anode and a KCl electrolyte reservoir separated from the sample by a 25 ยตm membrane (FEP). The main body of the OroboPOS is made of PEEK. With application of a polarization voltage (0.8 V), a current is obtained as an amperometric signal, which is converted to a voltage.
|info=[https://www.oroboros.at/index.php/product/orobopos/ '''Product details and purchase information''']


Shipment: OroboPOS are protected in a transparent perspex vial screwed onto a blue POM base, and shipped with the O2k in the [[O2k-Service Box]].
|product id=26100-01
|product type=O2k, O2k-Core Unit, OroboPOS
|info=Previous Product ID 26100-24, [[MiPNet08.04]], [[Gnaiger_1983_POS]]
|product image=[[File:OroboPOS sensor head.jpg|180px|link=]]
}}
}}
* A spare (third) OROBoPOS may be added to the items ordered with the O2k-System.
== Additional resources ==


* For technical service (troubleshooting) in regard to the POS, see [[POS (technical service)]].
:::ยป [[MiPNet19.18B POS-service]]
:::ยป [[Gnaiger 1983 POS]]ย 
:::ยป [[Polarographic_oxygen_sensor]]
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}

Latest revision as of 17:41, 10 November 2020


                  


O2k-Open Support

OroboPOS



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

OroboPOS.JPG

The OroboPOS is a polarographic oxygen sensor (POS), with an amperometric mode of operation. The OroboPOS meets the highest quality criteria in terms of linearity, stability and sensitivity of the signal. The Clark type polarographic oxygen sensor (POS) remains the gold standard for measuring dissolved oxygen in biomedical, environmental and industrial applications over a wide dynamic oxygen range.

It consists of a gold cathode, a silver/silverchloride anode and a KCl electrolyte reservoir separated from the sample by a 25 ยตm membrane (FEP). The main body of the OroboPOS is made of PEEK. With application of a polarization voltage (0.8 V), a current is obtained as an amperometric signal, which is converted to a voltage.


Reference: Product details and purchase information

Additional resources

ยป MiPNet19.18B POS-service
ยป Gnaiger 1983 POS
ยป Polarographic_oxygen_sensor

MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry