|description=[[Image:SmartFluo.png|200px|right]]'''Smart Fluo-Sensor Green''': Excitation LED 525 nm (dominant wavelength) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, [[Filter-Cap]] equipped with [[Filter Set AmR]] for [[Amplex® UltraRed|Amplex UltraRed]] and [[TMRM]] measurements when delivered.  
|description=[[Image:SmartFluo.png|200px|right]]'''Smart Fluo-Sensor Green''': Excitation LED 525 nm (dominant wavelength) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, [[Filter-Cap]] equipped with [[Filter Set AmR]] for [[Amplex® UltraRed|Amplex UltraRed]] and [[TMRM]] measurements when delivered.  
|info=[[Smart Fluo-Sensor]]
|info=[https://www.oroboros.at/index.php/product/smart-fluo-sensor-green/ '''Product details and purchase information''']
}}
}}


 
== Additional resources ==
 
:::*[[O2k-Fluo Smart-Module]]
== Troubleshooting ==
:::* ''-See'': [[Defective fluorescence module]]
{{MitoPedia O2k and high-resolution respirometry
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}
}}

Latest revision as of 17:14, 16 March 2021


                  


O2k-Open Support

Smart Fluo-Sensor Green



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

SmartFluo.png

Smart Fluo-Sensor Green: Excitation LED 525 nm (dominant wavelength) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, Filter-Cap equipped with Filter Set AmR for Amplex UltraRed and TMRM measurements when delivered.