Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Syringe\500 mm3 51/0.41 mm"

From Bioblast
Β 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Product
{{Technical support}}
|description=Hamilton '''Syringe\500 mm<sup>3</sup> 51/0.41 mm''' for manual titrations, 500 mm<sup>3</sup> volume; injection needle fixed: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the [[Microsyringe\200 mm3\TIP2k]].
__TOC__
{{MitoPedia without banner
|abbr=
|description=[[File:Syringe 500 mm3 51 0.41 mm.JPG |right|180px]]Hamilton '''Syringe\500 mm<sup>3</sup> 51/0.41 mm''' for manual titrations, 500 mm<sup>3</sup> volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the [[Microsyringe\200 mm3\TIP2k]].
|info=[https://www.oroboros.at/index.php/product/syringe500-mm3-51-0-41-mm/ '''Product details and purchase information''']
}}


[[O2k-FluoRespirometer]] and [[Startup O2k-Respirometer]]: 1 included in the [[O2k-Titration Set]].
== Technical support ==
|product id=51500-01
::::* Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
|product type=O2k, TIP2k, Microsyringe, Titration Set
::::* Titration of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria.
|info=[[O2k-Titration Set]], [[TIP2k-Module]]
::::* Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration).
|product image=[[File:Syringe 500 mm3 51 0.41 mm.JPG |right|180px]]
::::* [[TIP2k-Module]]: gas bubble-free and gas-tight filling of the [[Microsyringe\200 mm3\TIP2k]] and the [[Microsyringe\500 mm3\TIP2k]], with a minimum waste of the stock solution.
|link=
::::* For safe an clean handling, place the syringe in the one of the [[Syringe Racks]].
}}
::::* [[MiPNet19.14 SOP Hamilton microsyringes | MiPNet19.14]] - SOP for manual O2k-titrations with Hamilton microsyringes.
==Uses==
*Injections of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria.
*[[TIP2k-Module]]: gas bubble-free and gas-tight filling of the [[Microsyringe\200 mm3\TIP2k]] and the [[Microsyringe\500 mm3\TIP2k]], with a minimum waste of the stock solution.




::Β» Go to [[OROBOROS O2k-Catalogue]], [[Purchase]]
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}

Latest revision as of 10:09, 11 November 2020


                  


O2k-Open Support

Syringe\500 mm3 51/0.41 mm



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

Syringe 500 mm3 51 0.41 mm.JPG

Hamilton Syringe\500 mm3 51/0.41 mm for manual titrations, 500 mm3 volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the Microsyringe\200 mm3\TIP2k.


Reference: Product details and purchase information


Technical support

  • Safety information: fixed needles are used with rounded tips, not usable for injection into tissues.
  • Titration of suspensions of isolated mitochondria: larger inner diameter avoids mechanical damage of the mitochondria.
  • Titration of large volumes of stock solutions into the O2k-Chamber (e.g. succinate at 50 mM final concentration).
  • TIP2k-Module: gas bubble-free and gas-tight filling of the Microsyringe\200 mm3\TIP2k and the Microsyringe\500 mm3\TIP2k, with a minimum waste of the stock solution.
  • For safe an clean handling, place the syringe in the one of the Syringe Racks.
  • MiPNet19.14 - SOP for manual O2k-titrations with Hamilton microsyringes.


MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry