  2024 Week 11
  2024 Week 16


* '''Mar-11 Mo'''
* '''Apr-15 Mo'''  
:{|
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|''' Why is it important to perform respirometry with permeabilized muscle fibers (pfi) under a high [O<sub>2</sub>] regime? '''<br>
|'''Do you observe either a zero or low raw O<sub>2</sub> signal when starting a measurement?'''<br>
Long diffusion distances in the pfi result in an O<sub>2</sub> diffusion limitation, which is overcome by increasing the O<sub>2</sub> partial pressure inside the chamber. Proper instrumental background correction is a must and O<sub>2</sub> dependence of ROS production should be considered.   <br>
Perform a test to evaluate whether this is related to an improperly positioned chamber or a faulty connection between the OroboPOS and the OroboPOS-Connector. <br>
- »'''[[Permeabilized muscle fibers]]'''«, »'''[[Oxygen flux - instrumental background]]'''« <br>
- »'''[https://wiki.oroboros.at/index.php/Oxygen_signal#Raw_signal Oxygen signal]'''«<br>
- communicated by »[[Grings Mateus]]« and »[[Cardoso Luiza]]«  
- communicated by »[[Grings Mateus]]« and »[[Schmitt Sabine]]«
|}
|}
----
----
* '''Mar-12 Tu'''  
* '''Apr-16 Tu'''  
----
----
* '''Mar-13 We'''  
* '''Apr-17 We'''
----
* '''Apr-18 Th'''  
:{|
:{|
| width="100" align="center" |[[Image:BEC-logo.png|100px|link=https://www.bioenergetics-communications.org/index.php/bec |Bioenergetics Communications]]
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|'''''Rewarded'' Open Access - compensating authors'''<br>
|''' How to store the POS overnight and up to several months? '''<br>
Together with the MiP''society'', BEC is raising funds to reward the first 10 papers accepted for publication in BEC in 2024: 600 EUR to attend EBEC2024 and 2-year MiP''membership''.
With the POS still in place, fill the O2k-chamber and receptacle of the loosely inserted stopper with 70 % EtOH, add the Cover-slip and switch off the O2K. <br>
-»[https://whydonate.com/en/fundraising/BEC Support open access in science]«<br>
- »'''[[MiPNet19.03 O2k-cleaning and ISS]]'''«<br>
- »[https://www.bioenergetics-communications.org/index.php/bec/about/submissions Submit a manuscript
- communicated by »[[Leo Elettra]]« and »[[Grings Mateus]
|}
|}
----
----
* '''Mar-14 Th'''
* '''Apr-19 Fr'''
:{|
| width="100" align="center" |[[Image:O2k-Publications.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Publications:_Topics |O2k-Publications in the MiPMap]]
|'''Mitochondrial ultrastructure and respiration are affected during EDL [''Extensor digitorum longus'' muscle] aging.''' <br>
* Fernando R, Shindyapina AV, Ost M, Santesmasses D, Hu Y, Tyshkovskiy A, Yim SH, Weiss J, Gladyshev VN, Grune T, Castro JP (2023) Downregulation of mitochondrial metabolism is a driver for fast skeletal muscle loss during mouse aging.  [[Fernando 2023 Commun Biol|»Bioblast link«]]
:from the O2k-Network »[[DE Leipzip Ost M]]«
|}
----
* '''Mar-15 Fr'''  
----
----


'''<big>Next Week</big>'''
'''<big>Next Week</big>'''
  2024 Week 12
  2024 Week 17


* '''Mar-18 Mo'''
* '''Apr-22 Mo'''
::::: '''[[EU-METAHEART MC2 Meeting 2024 Antalya TR]]''' Mar 18-21
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
|'''How can I evaluate the effect of one specific titration of a complex SUIT protocol?'''<br>
Flux control efficiencies express the change in respiration after a single step, in which there is a change in a metabolic control variable.<br>
- »'''[[Flux control efficiency]]'''«, »'''[[Metabolic control variable]]'''«<br>
- communicated by »[[Cardoso Luiza]]« and »[[Baglivo Eleonora]]«
|}
----
----
* '''Mar-19 Tu'''  
* '''Apr-23 Tu'''  
:::: 15:05 '''[[Gnaiger Erich|Erich Gnaiger]] presenting at [[EU-METAHEART MC2 Meeting 2024 Antalya TR]]''' - ''[[Donnelly_2024_EU-METAHEART_MC2_Meeting |Functional hypoxia in cardiac mitochondria: effects on oxidative phosphorylation, mitochondrial membrane potential, redox state of coenzyme Q, and calcium uptake]]''
 
----
----
* '''Mar-20 We'''  
* '''Apr-24 We'''  
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|''' What if ''Alert: Error in titrations!'' appears in your O2 analysis template file?  '''<br>
The O2 analysis template recognizes discrepancies between the protocol selected in the first tab and the imported marks. Check the titration sequence and mark names against the protocol copied from the DLD file.<br>
- »'''[[MiPNet24.06 Oxygen flux analysis - DatLab 7.4|O<sub>2</sub> flux analysis]]'''«<br>
- communicated by »[[Timon-Gomez Alba]]« and »[[Leo Elettra]]«
|}
----
----
* '''Mar-21 Th'''  
* '''Apr-25 Th'''
 
:{|
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
| width="100" align="center" |[[Image:O2k-Publications.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Publications:_Topics |O2k-Publications in the MiPMap]]
|''' How well do you handle your Hamilton syringes? What is a cleaning cycle?'''<br>
|'''"Our results further enhance the understanding and relevance of bioenergetic function in liver ischemia and transplantation and provide the basis for further consideration of these parameters as biomarkers in LT [liver transplantation]."''' <br>
"A syringe cleaning cycle consists of (1) filling an empty syringe with a washing solution while immersing [both the needle and] the base of the barrel into the washing solution, without fully removing the plunger, and (2) emptying the syringe into the waste beaker." <br>
* Meszaros AT, Weissenbacher A, Schartner M, Egelseer-Bruendl T, Hermann M, Unterweger J, Mittelberger C, Reyer BA, Hofmann J, Zelger BG, Hautz T, Resch T, Margreiter C, Maglione M, Komlódi T, Ulmer H, Cardini B, Troppmair J, Öfner D, Gnaiger E, Schneeberger S, Oberhuber R (2024) The predictive value of graft viability and bioenergetics testing towards the outcome in liver transplantation. [[Meszaros_2024_Transpl_Int|»Bioblast link«]]
- »'''[[MiPNet19.14 SOP Hamilton microsyringes]]'''«<br>
:from the O2k-Network »[[AT Innsbruck Schneeberger S]] and [[AT Innsbruck Oroboros]]«
- communicated by »[[Baglivo Eleonora]]« and »[[Timon-Gomez Alba]]«
|}  
|}
----
----
* '''Mar-22 Fr'''
* '''Apr-26 Fr'''
----
----

Revision as of 14:02, 15 April 2024

Gentle Science
Oroboros declares solidarity against the Russian aggression-war in Ukraine and against all aggression-wars worldwide. -  »More details
A future for Ukraine is the future of its science
2024 Week 16
  • Apr-15 Mo
O2k-Open SupportInfo: improve Do you observe either a zero or low raw O2 signal when starting a measurement?

Perform a test to evaluate whether this is related to an improperly positioned chamber or a faulty connection between the OroboPOS and the OroboPOS-Connector.
- »Oxygen signal«
- communicated by »Grings Mateus« and »Schmitt Sabine«


  • Apr-16 Tu

  • Apr-17 We

  • Apr-18 Th
O2k-Open SupportInfo: improve How to store the POS overnight and up to several months?

With the POS still in place, fill the O2k-chamber and receptacle of the loosely inserted stopper with 70 % EtOH, add the Cover-slip and switch off the O2K.
- »MiPNet19.03 O2k-cleaning and ISS«
- communicated by »Leo Elettra« and »Grings Mateus«


  • Apr-19 Fr

Next Week

2024 Week 17
  • Apr-22 Mo
MitoPedia
How can I evaluate the effect of one specific titration of a complex SUIT protocol?

Flux control efficiencies express the change in respiration after a single step, in which there is a change in a metabolic control variable.
- »Flux control efficiency«, »Metabolic control variable«
- communicated by »Cardoso Luiza« and »Baglivo Eleonora« 


  • Apr-23 Tu

  • Apr-24 We

  • Apr-25 Th
O2k-Publications in the MiPMap "Our results further enhance the understanding and relevance of bioenergetic function in liver ischemia and transplantation and provide the basis for further consideration of these parameters as biomarkers in LT [liver transplantation]."
  • Meszaros AT, Weissenbacher A, Schartner M, Egelseer-Bruendl T, Hermann M, Unterweger J, Mittelberger C, Reyer BA, Hofmann J, Zelger BG, Hautz T, Resch T, Margreiter C, Maglione M, Komlódi T, Ulmer H, Cardini B, Troppmair J, Öfner D, Gnaiger E, Schneeberger S, Oberhuber R (2024) The predictive value of graft viability and bioenergetics testing towards the outcome in liver transplantation. »Bioblast link«
from the O2k-Network »AT Innsbruck Schneeberger S and AT Innsbruck Oroboros«

  • Apr-26 Fr