Difference between revisions of "Template:O2k-OpenSupportAlert2021"
Tindle Lisa (talk | contribs) |
Tindle Lisa (talk | contribs) |
||
Line 2: | Line 2: | ||
</big>__TOC__ | </big>__TOC__ | ||
== Apr 2021 == | == Apr 2021 == | ||
*'''Apr-27 Tu''' | |||
:{| | |||
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Yellow-take care.png|25px|Take care]] | |||
|''' Why is the fluorescence signal constantly at 10 V or at 0 V?'''<br> | |||
Follow these steps to localize and solve the problem: | |||
<br> | |||
- »'''[[Troubleshooting:_fluorescence_module#Fluorescence_signal_is_constantly_at_10_V|Fluorescence signal is constantly at 10 V]]'''« and »'''[[Defective_fluorescence_module#Zero_fluorescence_signal|0 V fluorescence signal]]'''« | |||
|} | |||
---- | |||
*'''Apr-20 Tu''' | *'''Apr-20 Tu''' | ||
:{| | :{| |
Revision as of 08:04, 26 April 2021
- Currently Answered Questions from the »Oroboros Ecosystem Agenda«
Apr 2021
- Apr-27 Tu
Why is the fluorescence signal constantly at 10 V or at 0 V?
Follow these steps to localize and solve the problem:
- »Fluorescence signal is constantly at 10 V« and »0 V fluorescence signal«
- Apr-20 Tu
Noisy fluorescence signal?
Follow these steps to localize and solve the problem:
- »Noisy fluorescence signal«
- Apr-13 Tu
Do you know what to do when the fluorescence signal starts at a negative value?
A negative signal may be caused by wet Fluo-Sensors. For further information:
- »Negative fluorescence signal«
- Apr-06 Tu
A damaged OroboPOS-Holder may cause medium to leak from the O2k-Chamber.
See how you can check that the OroboPOS-Holders are intact.
- »O2k-OroboPOS-Holder«
Mar 2021
- Mar-25 Th
O2k-checklist: Get started with an O2k-experiment
The O2k-checklist provides an overview of all essential steps for starting an O2k-experiment.
- » MiPNet20.04_O2k-checklist«
- » communicated by »Cecatto Cristiane« and »Schmitt Sabine«
Feb 2021
- Feb-17 We
Do you know how to prepare permeabilized muscle fibers? The application of high-resolution respirometry in permeabilized muscle fibers provides a sensitive diagnostic tool for the analysis of mitochondrial (dys)function in small biopsy samples.
- »O2k-Videosupport: Fiber permeabilization«
- »Doerrier 2018 Methods Mol Biol«
- communicated by »Doerrier Carolina« and »Tindle-Solomon Lisa«
- Feb-08 Mo
Do you know how to properly insert the ISS-tip into the O2k-chamber?
With the stirrer bar still rotating, insert the ISS-tip to the bottom of the O2k-Chamber, so that it points away from you.
- »MiPNet19.03 O2k-cleaning and ISS: Section 2«
- communicated by »Doerrier Carolina«, »Cecatto Cristiane« and »Komlodi Timea«
- Feb-02 Tu
DatLab error messages: What do they mean and how to solve them?
- » DatLab error messages«
- communicated by »Garcia-Souza Luiz F« and »Tindle-Solomon Lisa«
Jan 2021
- Jan-11 Mo
Are you a beginner or need a refresher on using SUIT protocols with DatLab7.4?
- » O2k-Videosupport: How to perform an experiment with a SUIT DL-Protocol« and » Run DL-Protocol/Set O2 limit in DatLab «
- communicated by »Komlodi Timea« and Schmitt Sabine«