Difference between revisions of "Volume-Calibration Ring sV"

From Bioblast
(Created page with "{{Product |description='''Volume-Calibration Ring sV''' (A or B), white PVDF, attached to PEEK O2k-Stopper sV. |product...")
 
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Product
{{Technical support}}
|description='''Volume-Calibration Ring sV''' (A or B), white PVDF, attached to [[Stopper sV\black PEEK\conical Shaft\central Port | PEEK O2k-Stopper sV]].
__TOC__
|product id=3432A-01 or 3432B-01
{{MitoPedia without banner
|product type=O2k, Stopper
|abbr=
|info= <!-- [[MiPNet22.11 O2k-FluoRespirometer manual]] -->
|description=[[Image:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]]'''Volume-Calibration Ring sV''' (A or B), white PVDF, attached to [[Stopper sV\black PEEK\conical Shaft\central Port | PEEK O2k-Stopper sV]].
|product image= <!-- [[Image:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]] -->
|info=[https://www.oroboros.at/index.php/product/volume-calibration-ring-sv/ '''Product details and purchase information''']
}}
}}
__TOC__
{{Template:Technical support integrated}}


<!-- CHECK THE TEXT BELOW
== Technical support ==
== Technical support ==


::: '''Volume calibration of the [[O2k-Chamber]]'''
::: '''Volume calibration of the 0.5-mL [[O2k-chamber]]'''
::::* Loosen the stopper fixation rings (A) and (B) with the L-shaped Allen key (OroboPOS-Service Kit).
::::* Loosen the stopper fixation rings (A) and (B) with the Allen key.
::::* Follow the instructions in the O2k-Manual: [[MiPNet22.11 O2k-FluoRespirometer manual]]
::::* Follow the instructions in the O2k-Manual: [[MiPNet22.11 O2k-FluoRespirometer manual]]
::::* Tighten the screws of the fixation rings (A) and (B) gently with the Allen key to ensure that the calibration ring cannot be displaced. Tightening the screw with too much force may damage the thread of the calibration ring. Check for a sufficient fixation by trying to rotate the calibration ring.
::::* Tighten the screws of the fixation rings (A) and (B) gently with the Allen key to ensure that the calibration ring cannot be displaced. Tightening the screw with too much force may damage the thread of the calibration ring. Check for a sufficient fixation by trying to rotate the calibration ring.


[[Image:Volume calibration ring A+B aluminum for Stopper.jpg|right|400px]]
[[Image:Volume calibration ring A+B aluminum for Stopper.jpg|right|400px]]
== Innovation ==
:::: Replacing the (white) PVDF Volume-Calibration Ring with the (black) aluminum Volume-Calibration Ring allows for more force applied to tighten the ring, thus reducing the risk of a loose fit and the associated danger of altering the calibrated position.


-->


[[Category:Technical service]]
== Keywords ==
{{Template:Keywords: Chamber volume}}
 
 
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}

Latest revision as of 11:25, 11 November 2020


                  


O2k-Open Support

Volume-Calibration Ring sV



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

Volume calibration ring A+B PVDF for Stopper.jpg

Volume-Calibration Ring sV (A or B), white PVDF, attached to PEEK O2k-Stopper sV.


Reference: Product details and purchase information



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Technical support

Volume calibration of the 0.5-mL O2k-chamber
  • Loosen the stopper fixation rings (A) and (B) with the Allen key.
  • Follow the instructions in the O2k-Manual: MiPNet22.11 O2k-FluoRespirometer manual
  • Tighten the screws of the fixation rings (A) and (B) gently with the Allen key to ensure that the calibration ring cannot be displaced. Tightening the screw with too much force may damage the thread of the calibration ring. Check for a sufficient fixation by trying to rotate the calibration ring.
Volume calibration ring A+B aluminum for Stopper.jpg


Keywords


Questions.jpg


Click to expand or collaps



MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry