Stirrer-Bar\white PVDF\15x6 mm: Difference between revisions
Beno Marija (talk | contribs) m (Reverted edits by Beno Marija (talk) to last revision by Schmarl Johannes) |
Beno Marija (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
{{ | {{Technical support}} | ||
|description='''Stirrer-Bar\white [[PVDF]]\15x6 mm''', operated in the [[O2k-Chamber]] at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor ([[OroboPOS]]) placed in a position of maximum current of the medium. | __TOC__ | ||
{{MitoPedia without banner | |||
|abbr= | |||
|description=[[Image:Stirrer bar PVDF.jpg|right|180px]]'''Stirrer-Bar\white [[PVDF]]\15x6 mm''', operated in the [[O2k-Chamber]] at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor ([[OroboPOS]]) placed in a position of maximum current of the medium. | |||
Line 6: | Line 9: | ||
[[O2k-FluoRespirometer]]: 2 in [[O2k-Assembly Kit]]. | [[O2k-FluoRespirometer]]: 2 in [[O2k-Assembly Kit]]. | ||
* For dispatch of the [[O2k-FluoRespirometer]], the Stirrer-Bars are shipped in the [[O2k-Service Box]]. | |||
|info=[[MiPNet06.01 O2k-Overview]] | |info=[[MiPNet06.01 O2k-Overview]] | ||
}} | }} | ||
A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself. >> [[MiPNet19.03 O2k-cleaning and ISS]]. | ย | ||
== Additional resources == | |||
ยป A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself. >> [[MiPNet19.03 O2k-cleaning and ISS]]. | |||
ย | |||
ย | |||
{{MitoPedia O2k and high-resolution respirometry | |||
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | |||
}} |
Revision as of 16:36, 13 October 2020
Stirrer-Bar\white PVDF\15x6 mm |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Stirrer-Bar\white PVDF\15x6 mm, operated in the O2k-Chamber at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor (OroboPOS) placed in a position of maximum current of the medium.
Two units of this item are standard components of the O2k-Assembly Kit (O2k-FluoRespirometer).
O2k-FluoRespirometer: 2 in O2k-Assembly Kit.
- For dispatch of the O2k-FluoRespirometer, the Stirrer-Bars are shipped in the O2k-Service Box.
Reference: MiPNet06.01 O2k-Overview
Additional resources
ยป A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself. >> MiPNet19.03 O2k-cleaning and ISS.
MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry