Oroboros FAQ
Applications and samples
Which are the most common applications of the OROBOROS Oxygraph-2k (O2k)?
The O2k is used in basic and applied research to study the respiration of tissues, cells and mitochondria. Fairly simple to highly complex, comprehensive experimental protocols can be applied to assess either basal mitochondrial characteristics or obtain diagnostic insight into respiratory pathways. Topically, studies using the O2k range from comparative physiological investigations addressing evolutionary and environmental aspects of mitochondrial metabolism over the energetics related to exercise physiology, nutrition and life style, to aspects of clinical interest such as the impact of metabolic diseases, cancer, or pharmacological interventions.
- The most prominent applications of the O2k
- Studies on exercise physiology;nutrition;life style
- Diagnosis of acquired and genetic mitochondrial diseases
- Diagnosis of myopathies and neuromuscular pathologies
- Studies on cell function and cell death - apoptosis and necrosis
- Measurement of oxidative stress
- Studies on ischemia-reperfusion injury
- Studies on aging and senescence
- Pharmacological tests
- Studies on Diabetes 2
- For more applications, browse through the 4713 O2k-Publications in the MiPMap.
What is high-resolution respirometry and what is so special about it?
High-resolution respirometry is the method of choice when aiming at investigating mitochondrial function either in intact cells or various types of mitochondrial preparation. Combining instrumental accuracy and reliability with versatility of applicable protocols - allowing practically unlimited addition and combination of substrates, inhibitors and uncouplers - mitochondrial respiratory pathways may be analyzed in detail to evaluate even minor alterations in respiratory pathway control and/or capacity. The O2k is a sole source apparatus, with no other available instrument meeting its specifications for high-resolution respirometry. High-resolution respirometry (HRR) is based on the O2k, combining chamber design, application of oxygen-tight materials, electrochemical and optical sensors, Peltier-temperature control and software features (DatLab) to obtain the unique sensitive and quantitative resolution of oxygen concentration and oxygen flux, with both, a closed- and open-chamber mode of operation.
Is the O2k easy to use in standard applications of mitochondrial respiration?
Most 'oxygraphs' are designed for analyzing isolated mitochondria. Which types of samples can be analyzed with the O2k?
Can the O2k be applied for the measurement of oxygen consumption in delicate mammalian cells, when limited numbers of cells are available?
Can the O2k be applied for measuring human biopsies?
Can the O2k be applied to measure tissue oxygen concentration?
Can the O2k be applied for measurement of oxygen consumption in adherent cells?
How many parameters can be measured simultaneously?
Software compatibility
Does DatLab software run on MAC devices?
O2k in comparison with other devices
Why buy an O2k and not a different oxygraph?
How and where to buy
Do you have any distributors in my country?
With the exception of the countries listed below, OROBOROS INSTRUMENTS has a direct-sales approach. This means, we generally sell our products directly to the end user. If required by the end user, it is possible to cooperate with a distributor. We cooperate with our distributors in the following countries:
- China: CN Beijing Zenda.
- Taiwan: TW Taoyuan Sunpoint.
- Republic of Korea: KR Seoul Mymed.
- Australia: AU Adelaide AIMedical.
- New Zealand: NZ Auckland GBC BioMed.
- Japan: JP Tokyo Sanyo. We are also open to requests for specific distributors as well as direct sales.
- Malaysia: MY Puchong Selangor Saujana Saintifik. We are also open to requests for specific distributors as well as direct sales.
How do I obtain price information on the O2k?
Whom do I contact to buy an O2k
Delivery content, warranty and support
How long from order till delivery?
Does the purchase include installation, setup and training?
- Installation and setup
On-site installation and setup is not included in the purchase of an O2k-Core. Setup and installation are usually performed by the customers themselves with the help of our detailed and user-friendly O2k-Manual which is sent out with the O2k. In addition, the manual can also be easily down-loaded form our website (O2k-Manual). There is also a section for technical service. Our technical specialists, based here in Innsbruck, can also assist in helping to locate and solve any technical problems, should these arise. Based on our experience and feedback received from customers all over the world, we are confident that you will easily master the set-up and installation.
- Training
Does the O2k-Core include a PC or do we have to purchase it separately?
Is it possible to extend the warranty period?
Are taxes and duty fees included in the price?
Do you offer the option to lease or rent your instruments?
Are you registered with System for Award Management (SAM)?
Software compatibility
- No. The DatLab software is designed for Windows operating systems.
O2k in comparison with other devices
How and where to buy
- With the exception of the countries listed below, OROBOROS INSTRUMENTS has a direct-sales approach. This means, we generally sell our products directly to the end user. If required by the end user, it is possible to cooperate with a distributor.
- We cooperate with our distributors in the following countries:
- China: CN Beijing Zenda.
- Taiwan: TW Taoyuan Sunpoint.
- Republic of Korea: KR Seoul Mymed.
- Australia: AU Adelaide AIMedical.
- New Zealand: NZ Auckland GBC BioMed.
- Japan: JP Tokyo Sanyo. We are also open to requests for specific distributors as well as direct sales.
- Malaysia: MY Puchong Selangor Saujana Saintifik. We are also open to requests for specific distributors as well as direct sales.
- Further information under Purchase.
- In order to request a quote or order an O2k or spare parts, please contact our Admin Team: [email protected]
Delivery content, warranty and support
- The O2k is produced on demand, i.e. upon receipt of your purchase order. Therefore, the current lead time for delivery is six (6) weeks. Depending on the workload of our workshop, this time span may be shortened.
- Installation and setup
- On-site installation and setup is not included in the purchase of an O2k-Core. Setup and installation are usually performed by the customers themselves with the help of our detailed and user-friendly O2k-Manual which is sent out with the O2k. In addition, the manual can also be easily down-loaded form our website (O2k-Manual). There is also a section for technical service. Our technical specialists, based here in Innsbruck, can also assist in helping to locate and solve any technical problems, should these arise. Based on our experience and feedback received from customers all over the world, we are confident that you will easily master the set-up and installation.
- Training
- The purchase of an O2k includes a waived registration fee for our O2k-Workshop, which takes place at regular intervals all over the world. For more information on our upcoming O2k-Workshops (IOC), please take a look at OROBOROS Events or send an Email to [email protected]
- Installation and setup
- No, the purchase of an O2k does not include a PC. However, a laptop or a PC (PC Requirements) is required to connect the O2k and run the required software (DatLab).
- Yes, it is possible to extend the warranty period by a total of three years. For more details, please contact our office: [email protected].
- No, our offer does not include any taxes or any applicable duty fees. Please consider this when budgeting the purchase.
- It is possible to either lease the O2k over the course of three years, after which the instrument passes over into your ownership. Furthermore, you can rent an instrument for a short period (e.g. several weeks or months) if you need to improve your throughput for a specific study or experiment.
- Yes.