Flux baseline correction: Difference between revisions

From Bioblast
(Created page with "{{MitoPedia |abbr=Baseline |description='''Flux baseline correction''' reduces the baseline value from all respiratory control states. }} {{MitoPedia concepts}} {{MitoPedia metho...")
ย 
(added technical support banner)
ย 
(9 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{MitoPedia
{{Technical support}}
|abbr=Baseline
{{MitoPedia without banner
|description='''Flux baseline correction''' reduces the baseline value from all respiratory control states.
|abbr=bc
|description='''Flux baseline correction''' provides the option to display the plot and all values of the [[flux]] (or [[flow]], or [[flux control ratio]]) as the total flux, ''J'', minus a baseline flux, ''J''<sub>0</sub>.
''J<sub>V</sub>''(bc) = ''J<sub>V</sub>'' - ''J<sub>V</sub>''<sub>0</sub>
''J<sub>V</sub>'' = (d''c''/d''t'') ยท ''ฮฝ''<sup>-1</sup> ยท ''SF'' - ''Jยฐ<sub>V</sub>''
For the oxygen channel, ''J<sub>V</sub>'' is O2 flux per volume [pmol/(sยทml)] (or volume-specific O<sub>2</sub> flux), ''c'' is the oxygen concentration [nmol/ml = ยตmol/l = ยตM], d''c''/d''t'' is the (positive) slope of oxygen concentration over time [nmol/(s ยท ml)], ''ฮฝ''<sup>-1</sup> = -1 is the stoichiometric coefficient for the reaction of oxygen consumption (oxygen is removed in the chemical reaction, thus the stoichiometric coefficient is negative, expressing oxygen flux as the negative slope), ''SF''=1,000 is the scaling factor (converting units for the amount of oxygen from nmol to pmol), and ''Jยฐ<sub>V</sub>'' is the volume-specific background oxygen flux ([[Instrumental background oxygen flux]]). ''Further details'': [[Flux / Slope]].
}}
{{MitoPedia methods
|mitopedia method=Respirometry, Fluorometry
}}
}}
{{MitoPedia concepts}}
{{MitoPedia methods}}
{{MitoPedia O2k and high-resolution respirometry
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=DatLab
|mitopedia O2k and high-resolution respirometry=DatLab
}}
}}
{{MitoPedia topics}}

Latest revision as of 11:50, 25 March 2022


                  


O2k-Open Support

Flux baseline correction



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

Flux baseline correction provides the option to display the plot and all values of the flux (or flow, or flux control ratio) as the total flux, J, minus a baseline flux, J0.

JV(bc) = JV - JV0
JV = (dc/dt) ยท ฮฝ-1 ยท SF - JยฐV

For the oxygen channel, JV is O2 flux per volume [pmol/(sยทml)] (or volume-specific O2 flux), c is the oxygen concentration [nmol/ml = ยตmol/l = ยตM], dc/dt is the (positive) slope of oxygen concentration over time [nmol/(s ยท ml)], ฮฝ-1 = -1 is the stoichiometric coefficient for the reaction of oxygen consumption (oxygen is removed in the chemical reaction, thus the stoichiometric coefficient is negative, expressing oxygen flux as the negative slope), SF=1,000 is the scaling factor (converting units for the amount of oxygen from nmol to pmol), and JยฐV is the volume-specific background oxygen flux (Instrumental background oxygen flux). Further details: Flux / Slope.

Abbreviation: bc


MitoPedia methods: Respirometry, Fluorometry 


MitoPedia O2k and high-resolution respirometry: DatLab 

Cookies help us deliver our services. By using our services, you agree to our use of cookies.