|description='''Stopper\black PEEK\conical Shaft\central Port''': with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), [[Volume-Calibration Ring]] (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings, with 8 spare O-rings ([[O-ring\Viton\12.5x1 mm]]). The black PEEK stoppers are required for optical O2k-MultiSensor Modules | |description='''Stopper\black PEEK\conical Shaft\central Port''': with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), [[Volume-Calibration Ring]] (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings, with 8 spare O-rings ([[O-ring\Viton\12.5x1 mm]]). The black PEEK stoppers are required for optical O2k-MultiSensor Modules. | ||
Two units of this item are standard components of the [[O2k-Assembly Kit]]. | Two units of this item are standard components of the [[O2k-Assembly Kit]]. | ||
Line 15: | Line 15: | ||
== O2k-Manual == | == O2k-Manual == | ||
=== Stoppers and optical measurements === | === Stoppers and optical measurements === | ||
:::: Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements | :::: Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements. If necessary, replace the previous [[Stopper\white PVDF\conical Shaft\central Port |white PVDF stoppers]]. The black stoppers can be used for all HRR applications in general. See [[MiPNet22.11 O2k-FluoRespirometer manual]] for calibration of the [[O2k-Chamber]] volume, which is identical for PEEK and PVDF stoppers. |
Revision as of 15:53, 9 September 2020
Stopper\black PEEK\conical Shaft\central Port
Description | Stopper\black PEEK\conical Shaft\central Port: with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), Volume-Calibration Ring (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings, with 8 spare O-rings (O-ring\Viton\12.5x1 mm). The black PEEK stoppers are required for optical O2k-MultiSensor Modules.
Two units of this item are standard components of the O2k-Assembly Kit. |
---|---|
Product ID | 24000-01 |
Type | O2k, O2k-Assembly Kit, MultiSensor, Stopper |
Link | O2k-Assembly Kit |
Image |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Stoppers for O2k-FluoRespirometer
- The stoppers are placed in the O2k-Service Box for shipment of the O2k-FluoRespirometer.
O2k-Manual
Stoppers and optical measurements
- Use only black PEEK stoppers in conjunction with optical measurements. If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See MiPNet22.11 O2k-FluoRespirometer manual for calibration of the O2k-Chamber volume, which is identical for PEEK and PVDF stoppers.